Q-pak for Air Pollution Control Scrubber
Scrubber, Wet Scrubber, Carbon Scrubber, Scrubbers, Centrifugal Scrubber, Air Scrubber, Gas Scrubber, Ammonia Scrubbers, Wet Scrubber Manufacturers, Ammonia Scrubber, Air Pollution Control Scrubber
Typical Two Stage Odour Control System Using Q-PAC
- Air Flow = 85 000 M3/hr
- Temperature = 26.7°C
- H2S Inlet Concentration = 35 ppmv
- CO2 Concentration = ambient 370 ppmv
- Tower Diameters = 3 Meters
- Superficial Gas Velocity = 3,3 m/sec
First Stage
- ~ 90% H2S Efficiency
- Packing = 2,0 m Q-PAC
- Liquid Flow = 18,8 L/sec
- Sump pH ± 12.5
- Q-PAC Pressure Drop = 10 pa
- Caustic Strength = 45%
- Theoretical Caustic Consumption = 60 L/hr
|